Time Resolved In Situ Tvj Measurements of 6.5 kV IGBTs during Inverter Operation

Although the device temperature is one of the most critical parameters in the dimensioning of an inverter, experimental studies focusing on the virtual junction temperature (Tvj) in running inverter are scarcely found. In this work the feasibility of four different practical methods is compared. Special focus is set on routines with a high time resolution that enables tracking of the time-dependent-temperature during one period of the sinusoidal output current. Details of the procedures are explained and compared with simulations. The dimensioning of an inverter application requires qualified knowledge of the stress imposed on the semiconductor devices. All electrical parameters are easily accessible by modern current and voltage probes and standard oscilloscope data recording. The chip temperature during inverter operation at the moment is seldom experimentally determined. The thermal dimensioning is normally done using typical or worst case values specified by the supplier (e.g. thermal resistance of IGBT module and cooler) in combination with simulations of the generated losses.

• 545.50 KB
• 31/01/2011